GreatWall XSP-EP250WV38B
250W AC-DC with 3.8V DC output for energy saving.
90~264Vac Input.
Complies with UL, Europe CE, RoHS required.
High Reliability 3 years Warranty basically.
1 Electrical characteristic
1.1 Input characteristic
1.1.1 Input basic characteristics
Item | Unit | Min | Typical | Max | Remark |
Input voltage | Vac | 90 | 110/220 | 264 | |
Safety cerficate voltage | Vac | 100 | / | 240 | |
Input frequency | HZ | 47 | 50/60 | 63 | |
Input current | A | / | 3 | / | 100Vac input, full load |
Power factor | % | 98 | / | / | 115Vac, 50/60Hz, full load (Test after 10 minutes operation below -25℃) |
95 | / | / | |||
Input rush current | A | / | / | 40(110V) 65(220V) | 25℃,cold start |
Input phase | / | / | Single | / |
1.1.2 Input protection characteristics
Item | Unit | Min | Typical | Max | Remark |
Input UVP | Vac | / | / | 80 | Auto recovery hiccup mode us allowed, hysteresis voltage should not less than 5V |
Safety UVP recovery point | Vac | / | / | 85 | |
Input OCP | / | / | / | / | L line connects to a fus |
1.2 Output characteristic
1.2.1 Output basic characteristics
Item | Unit | Min | Typical | Max | Remark |
Output power | Watts | / | 195 | / | 180Vac~264Vac, refer to 1.2.3 |
/ | 136.5 | / | 90Vac~132Vac, refer to 1.2.3 | ||
Output voltage | / | +3.7 | +3.9 | +4.1 | 90Vac~264Vac |
Output current | A | 0 | / | 50 | 187Vac~264Vac |
0 | / | 35 | 90Vac~132Vac | ||
Efficiency | % | 88 | / | / | 25C,220Vac, above 50% rated Load |
85 | / | / | 25C,110Vac, above 50% rated Load |
Item | Unit | Min | Typical | Max | Remark |
Input voltage stability | % | / | / | ±5 | Full range of input voltage and load |
Line regulation | % | / | / | ±5 | 90Vac~132Vac ,187Vac~264Vac, Rated load |
Load regulation | % | / | / | ±5 | Rated voltage |
Ripple and noise | mVp-p | / | / | 200(300@-25 C) | 0. 1μF+10μF capacitors connect to output when testing, 20MHz bandwidth for oscilloscope; Power should operate at least for 10min before testing -25 |
Transient response deviation | / | / | / | -20%, +15% | Range of variation: 5%~100%~5% Rate of change:1A/µs, Cycle of change: 0.05mS~100mS |
Over/Under shoot of power on/off | % | / | / | ±10 | |
Delay time of power on | S | / | / | 3 | |
Rise time | mS | / | / | 30 | Rated voltage |
Hold up time | mS | 4 | / | / | 80% Load, 115Vac/220Vac,50Hz/60Hz |
Capacitive load | µF | / | / | 10,000 | Resistive load |
1.2.2 Output protection characteristics
Item | Unit | Min | Typical | Max | Remark |
OVP | Vdc | / | / | 5.5 | 20% Load, 115Vac/230Vac, Manual Recovery |
OCP | A | 55 | / | 75 | Auto recovery, 230Vac |
OSP | / | / | / | / | Auto recovery |
OTP(ambient temperature) | ℃ | 75 | 85 | 95 | Rated voltage, 100% Load, Manual Recovery |
1.2.3 Load/Input voltage graph
1.2.4 Load/Temperature graph
2 Environment
Item | Unit | Min | Typical | Max | Remark |
Operating Temperature | ℃ | -40 | 25 | 70 | Refer to 1.2.4 |
Storage Temperature | ℃ | -40 | 25 | 85 | |
Relative humidity | % | 10 | / | 95 | No condensation |
Operating Altitude | m | 0 | 0 | 5, | |
Heat dispersion | Air-cooled by 3CFM fans, radiating area greater than 30000px2 |
3 EMC
ITEM | INDEX REQUIRMENTS | STANDARD |
CE | CLASS B-6dB (Test in case, add high frequency filter to AC line) | CISPR 22 |
RE | CLASS B (Test in case) | CISPR 22 |
ESD | Contact discharge: 8kV(CLASS B); Air discharge: 15kV(CLASS B) | IEC61000-4-2 |
EFT/B | 2kV(criterion B) | IEC61000-4-4 |
DIP | Drop to 0%UT, duration 10ms (110Vac, Criterion B); Drop to 0%UT, duration 20ms (220Vac, Criterion B); Drop to 70%UT, duration 500ms (Criterion B); Drop to 0%UT, duration 5000ms (Criterion C) | IEC61000-4- 11 |
FLICKER | Pst≤1; Plt≤0.65; dc≤3.3%; dmax ≤4%; Duration of d(t) exceed 3.3% ≤500mS | IEC61000-3-3 |
SURGE | DM: 1KV, 2Q; CM: 2KV, 10Q; Criterion B (1.2/50 ㎲ for open-circuit voltage and 8/20 ㎲ for short-circuit current) | IEC61000-4-5 |
4 Safety
ITEM | Grade | STANDARD |
Input to output | 3,000VAC | Test for 1 minute, less than 10mA leakage. |
Input to earth | 1,500VAC | Test for 1 minute, less than 10mA leakage. |
Insulating resistance | 10MΩ | Input to output, Input to earth, Output to earth, 500Vdc for 1 minute, isolation resistance shall not be less than 10Mohm. |
Leak current | Class I:≦1mA | Input 264Vac/50Hz. |
5 Reliability
MTBF: greater than 100,000 hours. Rated voltage, rated load @25℃.
6 Special requirements
PCB material: FR4
Bulk capacitor rated voltage: 450V
Triple defense adhesive should be used in the PCB soldering surface
Could be installed vertically
7 Physical drawing
7. 1 Product Dimension: 180mm*55mm*30mm
7.2 Label
8 Packaging
8.1 PSU net weight: 1.18kg (±50g) 16pcs/ carton box
9 Quality assurance
The repair term of the product for free is 3 years from delivery.
The way of free repair is replacement or repair of defective products.
When repairing the product, the clear reason or basis has to be presented based on part list and part arrangement drawing attached in this document.
If the specification of provided parts is in need of revision, confirmation from quality management division of confirmation partner is required.
When there occurs failure or damage on the product, contact quality management division of our company. DO NOT open the product without permission from our company. Otherwise, the repair is not possible as a rule.